Closed Loop Cooling Towers
WPI’s WPCL-Series closed loop cooling towers incorporate WPI’s proven WP-Series FRP cooling towers with stainless steel heat exchangers, stainless steel strainers, and circulation pumps all assembled on a common skid. Whaley Products has been packaging these systems for a variety of industrial needs for many years. Whether you’re company is needing the clean water loop for HVAC, industrial, oil & gas, machining, milling, chemical, dry-cleaning, or any other application, the WPCL-Series closed circuit cooling tower will provide you with a long lasting, cost efficient, energy efficient cooling solution. Other configurations include the CLIO-Series indoor/outdoorsetup that incorporates an outdoor cooling tower and an indoor heat transfer/pump-tank skid. For increased capacity, check out the multi-cell CLS-Series closed circuit cooling towers.
WPCL-Series Capacities Available:
Model
|
Tower Tons / KW
|
Flow: GPM
|
HX Type
|
Pump
|
Strainer In/Out
|
Strainer Max Flow
|
PDF literature
|
WPCL650-10 |
10 Ton/44KW
|
30 GPM
|
PHX
|
1.0 HP, #11
|
2″ NPT Bottom
|
100 gpm
|
|
WPCL650-15 |
15 Ton/66KW
|
45 GPM
|
PHX
|
1.5 HP , #126
|
2″ NPT Bottom
|
100 gpm
|
|
WPCL850-20 |
20 Ton/88KW
|
60 GPM
|
PHX
|
2.0 HP, # 16
|
2″ NPT Bottom
|
100 gpm
|
|
WPCL850-25 |
25 Ton/110KW
|
75 GPM
|
PHX
|
2.0 HP, #16
|
2″ NPT Bottom
|
100 gpm
|
|
WPCL1250-30 |
30 Ton/132KW
|
90 GPM
|
PHX
|
3.0 HP, #17
|
2″ NPT Bottom
|
100 gpm
|
|
WPCL1250-40 |
40 Ton/176KW
|
120 GPM
|
PHX
|
3.0 HP, #17
|
3″ NPT Bottom
|
200 gpm
|
|
WPCL1550-50 |
50 Ton/220KW
|
150 GPM
|
PFHX
|
5.0 HP, #17
|
3″ NPT Bottom
|
200 gpm
|
|
WPCL1550-75 |
75 Ton/330KW
|
225 GPM
|
PFHX
|
7.5 HP, #15
|
4″ flange side
|
350 gpm
|
|
WPCL1850-100 |
100 Ton/440KW
|
300 GPM
|
PFHX
|
10 HP, #15
|
4″ flange side
|
350 gpm
|
|
WPCL1850-125 |
125
Ton/550KW
|
375 GPM
|
PFHX
|
10 HP, #56F
|
4″ flange side
|
350 gpm
|
For higher capacity, see our CLS-Series Closed Circuit Cooling Towers
UNIT CAPACITY RATING:
3 GPM / ton from 95°F to 85°F (at 78°F wet bulb).
Whaley Towers have a life expectancy of 20+ years.
How does WPI accomplish this? Very simple.
WP Series Cooling Tower Features
Construction material details:
Non-corrosive FRP(Fiberglass Reinforced Polyester) marine grade resins
Surface layer containing pigmented gel coat
Ultraviolet (UV) inhibitor included as an additive to the composite matrix.
Accu-Pac cross fluted fill pack:
Improves water distribution by splitting water stream 8 times in a 12” vertical path as it descends through the fill pack
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC
Accu-Pac counterflow cellular drift eliminators
High surface area provides maximum performance at minimum pressure drop
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC
Cellular Inlet Louvers installed:
Improve air flow into cooling tower
Prevent debris from entering
Eliminate water splash-out that can cause icing, water treatment chemical loss
Restricts amount of sunlight into cooling tower impeding algae growth
Reduce noise from tower
Improve tower’s appearance
Constructed entirely of CTI (Cooling Tower Institute) Standard 136 PVC
Lightweight ABS plastic non-clogging Dek-Spray nozzles
serviceable at temperatures up to 180F/82C
Results in less system weight & piping cost
Steel Tower platform with fork slots
4″ C-Channel
Sheered sheet metal cover with cut-out for bottom tower drain
Painted with gray Macropoxy 646 Fast Cure Epoxy (high solids, high build, polyamide epoxy designed to protect steel and concrete in industrial exposures)
Side or bottom outlet drain
Location and size of outlet fitting determined according to your requirements
Other Features
Schedule 80 distribution header |
PVC inlet flange |
½” automatic water makeup |
Stainless steel hardware |
Glossy white color |
Direct drive fan motors |
Axial fan blades |